swc_error.h
SPARK Wireless Core error codes.
- Copyright
Copyright (C) 2021 SPARK Microsystems International Inc. All rights reserved.
- License
This source code is proprietary and subject to the SPARK Microsystems Software EULA found in this package in file EULA.txt.
- Author
SPARK FW Team.
Enums
-
enum swc_error
Wireless API error structure.
Values:
-
enumerator SWC_ERR_NONE = 0
No error occurred
-
enumerator SWC_ERR_NOT_INITIALIZED
The Wireless Core is not initialized
-
enumerator SWC_ERR_NOT_ENOUGH_MEMORY
Not enough memory is allocated by the application for a full Wireless Core initialization
-
enumerator SWC_ERR_NULL_PTR
A NULL pointer is passed as argument
-
enumerator SWC_ERR_FAST_SYNC_WITH_DUAL_RADIO
Fast sync and dual radio are enabled but are incompatible
-
enumerator SWC_ERR_PAN_ID
The configured PAN ID is invalid
-
enumerator SWC_ERR_NETWORK_ROLE
The configured network role is invalid
-
enumerator SWC_ERR_SLEEP_LEVEL
The configured sleep level is invalid
-
enumerator SWC_ERR_IRQ_POLARITY
The configured IRQ polarity is invalid
-
enumerator SWC_ERR_SPI_MODE
The configured SPI mode is invalid
-
enumerator SWC_ERR_MODULATION
The configured modulation is invalid
-
enumerator SWC_ERR_FEC_RATIO
The configured FEC ratio is invalid
-
enumerator SWC_ERR_CCA_FAIL_ACTION
The configured CCA fail action is invalid
-
enumerator SWC_ERR_CCA_THRESHOLD
The configured CCA threshold is invalid
-
enumerator SWC_ERR_CCA_INVALID_PARAMETERS
The configured CCA parameters are invalid
-
enumerator SWC_ERR_LOCAL_ADDRESS
The configured local address is invalid
-
enumerator SWC_ERR_SOURCE_ADDRESS
The configured source address is invalid
-
enumerator SWC_ERR_DESTINATION_ADDRESS
The configured destination address is invalid
-
enumerator SWC_ERR_CONNECTION_ADDRESS
None of the connection’s addresses match with the local device’s address
-
enumerator SWC_ERR_ARQ_WITH_ACK_DISABLED
ARQ is enabled while ACK is not
-
enumerator SWC_ERR_THROTTLING_ON_RX_CONNECTION
Link throttling is enabled on an RX connection
-
enumerator SWC_ERR_THROTTLING_NOT_SUPPORTED
Link throttling is disabled on this connection
-
enumerator SWC_ERR_NO_PAYLOAD_MEM_ALLOC_ON_RX_CONNECTION
Payload memory allocation is not enabled on a RX connection
-
enumerator SWC_ERR_TX_PULSE_COUNT
The configured TX pulse count is invalid
-
enumerator SWC_ERR_TX_PULSE_COUNT_OFFSET
The configured TX pulse count offset is invalid
-
enumerator SWC_ERR_TX_PULSE_WIDTH
The configured TX pulse width is invalid
-
enumerator SWC_ERR_TX_PULSE_WIDTH_OFFSET
The configured TX pulse width offset is invalid
-
enumerator SWC_ERR_TX_PULSE_GAIN
The configured TX pulse gain is invalid
-
enumerator SWC_ERR_TX_GAIN_OFFSET
The configured TX pulse gain offset is invalid
-
enumerator SWC_ERR_RX_PULSE_COUNT
The configured RX pulse count is invalid
-
enumerator SWC_ERR_NO_BUFFER_AVAILABLE
There is no more payload buffer available from the queue
-
enumerator SWC_ERR_ADD_CHANNEL_ON_INVALID_CONNECTION
A channel is added on a connection using only auto-reply timeslots
-
enumerator SWC_ERR_INTERNAL
There is an internal Wireless Core error
-
enumerator SWC_ERR_ALREADY_CONNECTED
The Wireless Core is already connected.
-
enumerator SWC_ERR_NOT_CONNECTED
The Wireless Core is not connected.
-
enumerator SWC_ERR_DISCONNECT_TIMEOUT
The Wireless Core failed to disconnect within the timeout value.
-
enumerator SWC_ERR_PAYLOAD_TOO_BIG
The configured payload size exceeds the maximum value for the current connection configuration.
-
enumerator SWC_ERR_SECOND_RADIO_NOT_INIT
Dual radio is used but swc_node_radio_add() is not called twice
-
enumerator SWC_ERR_FRAGMENTATION_NOT_SUPPORTED
The function call is not supported when the frame fragmentation is enable on the connection. swc_connection_receive_to_buffer() should be use instead.
-
enumerator SWC_ERR_OUTIMPED
The configured output driver impedance is invalid
-
enumerator SWC_ERR_SEND_ON_RX_CONN
User tried to send on a connection that can’t send
-
enumerator SWC_ERR_ZERO_TIMESLOT_SEQ_LEN
Input parameter is out of acceptable value
-
enumerator SWC_ERR_ZERO_CHAN_SEQ_LEN
Zero value was given to channel sequence length
-
enumerator SWC_ERR_MIN_QUEUE_SIZE
Minimum queue size requirement not met
-
enumerator SWC_ERR_ZERO_TIMESLOT_COUNT
Zero was given to timeslot count
-
enumerator SWC_ERR_NULL_TIMESLOT_DURATION
Zero was given as timeslot duration for 1 or more timeslots
-
enumerator SWC_ERR_CHANGING_CONFIG_WHILE_RUNNING
User tried to change configuration while the SWC is running
-
enumerator SWC_ERR_SEND_QUEUE_FULL
The queue of the sender is full
-
enumerator SWC_ERR_SIZE_TOO_BIG
The payload sent is greater than the available space
-
enumerator SWC_ERR_RECEIVE_QUEUE_EMPTY
The queue of the receiver is empty
-
enumerator SWC_ERR_RX_OVERRUN
New payload received and dropped because the RX queue is full
-
enumerator SWC_ERR_TIMESLOT_CONN_LIMIT_REACHED
The maximum number of connection assigned to the time slot was already reached
-
enumerator SWC_ERR_NON_ZERO_PRIORITY_WITHOUT_CONN_ID
The connection priority is not equal to zero while the connection ID protocol is disabled.
-
enumerator SWC_ERR_NON_MATCHING_SAME_TIMESLOT_CONN_FIELD
Some connection fields must be identical in order for these connections to be used on the same time slot using the connection priority feature.
-
enumerator SWC_ERR_MULTI_RADIO_HAL_INVALID
The multi radio hal initialization is invalid.
-
enumerator SWC_ERR_MAX_CONN_PRIORITY
The priority of the connection is higher than the maximum priority.
-
enumerator SWC_ERR_BUFFER_SIZE_TOO_SMALL
The provided buffer size is too small to execute the operation.
-
enumerator SWC_ERR_INVALID_PARAMETER
The one of the specified parameter/s has an invalid value.
-
enumerator SWC_ERR_NOT_ALLOWED_CONN_PRIORITY_CONFIGURATION
The priority configuration of the connection is not allowed.
-
enumerator SWC_ERR_PRIO_NOT_ENABLE_ON_ALL_CONN
Connection priority feature is not enable on each connection sharing the same timeslot.
-
enumerator SWC_ERR_OPTIMIZATION_DELAY_TO_HIGH
The computed delay for the latency optimization feature is too high.
-
enumerator SWC_ERR_CHIP_RATE
The configured chip rate is invalid.
-
enumerator SWC_ERR_RANGING_NOT_SUPPORTED
The ranging feature is not supported.
-
enumerator SWC_ERR_CREDIT_FLOW_CTRL_WITH_ACK_DISABLED
Credit low control is enabled while ACK is not
-
enumerator SWC_ERR_CONTEXT_SWITCH_TRIGGER_IS_NULL
The context switch trigger has not been initialized.
-
enumerator SWC_ERR_ACK_NOT_SUPPORTED_IN_AUTO_REPLY_CONNECTION
The Wireless core doesn’t support acknowledge on anauto-reply connection.
-
enumerator SWC_ERR_ADD_RANGING_SETTINGS_ON_INVALID_CONNECTION
Ranging settings are added on a TX connection or a connection using a main timeslot.
-
enumerator SWC_ERR_RADIO_ID_INVALID
The radio ID provided is out of range.
-
enumerator SWC_ERR_CALIBRATION_MISSING
No saved calibration data found in HEAP; calibration required.
-
enumerator SWC_ERR_RADIO_NOT_FOUND
Radio model not found.
-
enumerator SWC_ERR_INVALID_TIMESLOT_SLEEP_LEVEL
Sleep level for one of the time slots is incorrect.
-
enumerator SWC_ERR_INVALID_PULSE_CONFIG_27M
Pulse configuration for 27MHz is not valid
-
enumerator SWC_ERR_INVALID_OPERATION_AFTER_SETUP
Operation must be done before SWC setup.
-
enumerator SWC_ERR_NO_CHANNEL_INIT
No channel are initialized in one of the connections
-
enumerator SWC_ERR_CHANNEL_OUT_OF_RANGE
Selected channel is out of range for the current radio model.
-
enumerator SWC_ERR_DYNAMIC_PHY_MODE_DISABLED
PHY mode was requested why the feature is disabled.
-
enumerator SWC_ERR_UNINITIALIZED_CONNECTION
Connection hasn’t been allocated and the pointer is null
-
enumerator SWC_ERR_CONNECTION_CREATION_FAILED
Failed to create connection due to internal error.
-
enumerator SWC_ERR_FRAME_CONFIGURATION_FAILED
Failed to configure frame due to internal error.
-
enumerator SWC_ERR_FAILED_TO_SET_CALLBACK
Failed to set callback due to internal error.
-
enumerator SWC_ERR_NODE_NOT_INITIALIZED
The node instance hasn’t been initialized before.
-
enumerator SWC_ERR_NOT_MATCHING_NETWORK_ID
Network ID doesn’t match the Network ID set during node init.
-
enumerator SWC_ERR_FLUSH_QUEUE_WHILE_RUNNING
User tried to flush a connection’s queue while the SWC is running
-
enumerator SWC_ERR_INVALID_OPERATION_AFTER_SWC_LOCK
Connection settings cannot be modified after the connection priority or slot priority has been initialized. Ensure that these feature API calls are the last ones made when configuring a connection.
-
enumerator SWC_ERR_INVALID_OPERATION_CONN_PRIO_ENABLED
-
enumerator SWC_ERR_INVALID_OPERATION_SLOT_PRIO_ENABLED
Connection priority feature cannot be use if slot priority is enabled.
-
enumerator SWC_ERR_NONE = 0